Model  | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
CDX800F6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.50%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.11 G/ºC  | 
       ±0.03%/C°   | 
       Brass   | 
     
CDX801F6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.50%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.11 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass   | 
     
CDX802F6/8/10   | 
       6/8/10   | 
       0.60  | 
       1.55  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.50%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.11 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
MDX801F6/8/10   | 
       6/8/10   | 
       0.50  | 
       1.7  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.50%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.11 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
MDX802F6/8/10(Flexible)  | 
       6/8/10   | 
       0.35  | 
       1.2  | 
       0.5±0.1  | 
       0.15  | 
       DC-20kHZ   | 
       30kG   | 
       ±0.50%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.11 G/ºC   | 
       ±0.03%/C°   | 
        
          Polytesin    | 
     
High Precision Transverse Probes
* The length  of probe could be customized; array probe is optional  
* We can add temperature sensor  in the probe   
*If test frequency higher  than 800Hz, suggest to choose non-metal packaging, inorder to avoid affecting  test accuracy   
* Suitable for DX-150,  DX-160
 
         Model   | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
MCDX800F6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
MCDX801F6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass   | 
     
MCDX802F6/8/10   | 
       6/8/10   | 
       0.60  | 
       1.55  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
MMDX801F6/8/10   | 
       6/8/10   | 
       0.50  | 
       1.7  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
MMDX802F4/6/8 Flexible  | 
       4/6/8   | 
       0.35  | 
       1.2  | 
       0.5±0.1  | 
       0.15  | 
       DC-50kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Resin   | 
     
MMDX803F4/6/8 Flexible  | 
       4/6/8   | 
       0.25  | 
       0.7  | 
       0.5±0.1  | 
       0.10  | 
       DC-50kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Resin   | 
     
Ultra-high Precision Transverse probes
 
     * The length of probe could be customized;  array probe is optional  
     * We can add temperature sensor  in the probe
     *If test frequency higher than  800Hz, suggest to choose non-metal packaging, inorder to avoid affecting test  accuracy      
     * Suitable for DX-180,  DX-210, DX-360 
|           Model   | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
HCDX800F6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       100kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
HCDX801F6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       100kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass   | 
     
HCDX802F6/8/10   | 
       6/8/10   | 
       0.60  | 
       1.55  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       100kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
HMDX801F6/8/10   | 
       6/8/10   | 
       0.50  | 
       1.7  | 
       1±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       100kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
HMDX802F4/6/8 Flexible  | 
       6/8/10   | 
       0.35  | 
       1.2  | 
       0.5±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       100kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.10 G/ºC   | 
       ±0.03%/C°   | 
        
          Resin   | 
     
HMDX803F4/6/8 Flexible  | 
       6/8/10   | 
       0.25  | 
       0.7  | 
       0.5±0.1  | 
       0.10  | 
       DC-30kHZ   | 
       100kG   | 
       ±0.5%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.10 G/ºC   | 
       ±0.03%/C°   | 
       Resin   | 
     
Flexible High Precision Transverse Probes (suitable for special circumstance or high frequency) Transverse Probes

Model  | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic    linearity (%rdg)  | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
CDX800F-R6/8/10   | 
       6/8/10   | 
       1.50  | 
       2.4  | 
       1±0.1  | 
       0.15  | 
       DC-50KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+70°C     | 
       ±0.08 G/ºC    | 
       ±0.03%/C°   | 
       plastic   | 
     
CDX801F-R6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.4  | 
       1±0.1  | 
       0.15  | 
       DC-50KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+70°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       plastic  | 
     
CDX802F-R6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.3  | 
       1±0.1  | 
       0.15  | 
       DC-50KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+70°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       plastic    | 
     
High Precision Temperature Compension Type Hall Probes ( installed temperature sensor) Transverse Probes
Model  | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
MCDX800F-T6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+100°C     | 
       ±0.08 G/ºC    | 
       ±0.01%/C°   | 
       Brass   | 
     
MCDX801F-T6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass   | 
     
HCDX800F-T6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ  | 
       10OkG  | 
       ±0.05%to30kG   | 
       -50°Ct0+100°C     | 
       ±0.08    G/ºC    | 
       ±0.01%/C°  | 
        
          Brass    | 
     
HCDX801F-T6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ  | 
       10OkG  | 
       ±0.05%to30kG   | 
       -50°Ct0+100°C  | 
       ±0.08 G/ºC   | 
       ±0.01%/C°  | 
       Brass   | 
     
High Precision High Magnetic Field Type Hall Probes Transverse Probes
Model  | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
HCDX800F-H T 6/8/10  | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG±0.8%to50kG ±1.5%to100kG±5%to300kG  | 
       -20°Ct0+100°C     | 
       ±0.08G/ºC    | 
       ±0.01%/C°   | 
       Brass   | 
     
HCDX800F-H T 6/8/10  | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG±0.8%to50kG ±1.5%to100kG±5%to300kG  | 
       -20°Ct0+100°C   | 
       ±0.08G/ºC   | 
       ±0.01%/C°   | 
        
          Brass   | 
     
High Precision Low Magnetic Field Transverse Probes
Model  | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Full Scale    (Standard)   | 
       Magnetic linearity (%rdg)  | 
       Operating temp range  | 
       Zero temp coefficient (max)  | 
       Temp coefficient (max)  | 
       Stem    material   | 
     
LDX801F 8/10  | 
       8/10  | 
       2.6   | 
       10  | 
       2±0.1  | 
       0.1uT  | 
       300uT   | 
       ±0.5%To 100uT ±1.0%To300uT  | 
       -10ºCto+75ºC   | 
       ±0.08 G/ºC   | 
       ±0.05%/C°   | 
       plastics  | 
     
LDX801F 8/10  | 
       8/10  | 
       2.6   | 
       10   | 
       2±0.1  | 
       0.1uT   | 
       400uT   | 
       ±0.5%To 100uT ±1.0%To300uT  | 
       -10ºCto+75ºC   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       plastics  | 
     
High Precision High Temperature Resistance Temperature Compension Type Hall Probes ( installed temperature sensor)
 
     Transverse Probes 
   Model  | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
CDX800F-HT6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.015%/C°   | 
       Brass   | 
     
CDX801F-HT6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.015%/C°   | 
        
          Brass   | 
     
CDX802F-H6/8/10   | 
       6/8/10   | 
       0.60  | 
       1.55  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
MDX801F-H6/8/10   | 
       6/8/10   | 
       0.50  | 
       1.7  | 
       1±0.1  | 
       0.15  | 
       DC-800HZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
MDX802F-H6/8/10   | 
       6/8/10   | 
       0.35  | 
       1.2  | 
       0.5±0.1  | 
       0.15  | 
       DC-30kHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -50°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Resin   | 
     
High Precision Low Temperature Resistance Temperature Compension Type  Hall Probes (installed temperature sensor) 
        Transverse Probes  
            Model   | 
       L(cm)approx   | 
       T(mm)max   | 
       W(mm)   | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic linearity(%rdg)   | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
CDX800F-LT6/8/10   | 
       6/8/10   | 
       1.00  | 
       2.6  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±1.0%to30kG   | 
       -269°Ct0+75°C   | 
       ±0.08 G/ºC   | 
       ±0.015%/C°   | 
       Brass   | 
     
CDX801F-LT6/8/10   | 
       6/8/10   | 
       0.80  | 
       2.2  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±1.0%to30kG   | 
       -269°Ct0+75°C   | 
       ±0.08 G/ºC   | 
       ±0.015%/C°   | 
        
          Brass   | 
     
MDX801F-L6/8/10   | 
       6/8/10   | 
       0.50  | 
       1.7  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±1.0%to30kG   | 
       -269°Ct0+75°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
   