| Product Catalog: | 
Micro Hall Probes
| Product Overview: | 
Axial Probes
High Precision Axis Probes

High Precision Axis Probes
The length of probe could be customized; array probe is  optional  
     * We can add temperature sensor  in the probe
     * If test  frequency higher than 800Hz, suggest to choose non-metal packaging, inorder to  avoid affecting test accuracy  
   * Suitable  for dx-130, DX-150, DX-160
Model  | 
       L(cm)approx   | 
       D(mm) max  | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic    linearity (%rdg)  | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
1ADX800F 10/25/50  | 
       10/25/50   | 
       5.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC    | 
       ±0.03%/C°   | 
       Brass   | 
     
1ADX800F 10/25/50  | 
       10/25/50   | 
       3.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass   | 
     
1ADX802F 10/25/50  | 
       10/25/50   | 
       2.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
1ADX803F 10/25/50  | 
       10/25/50   | 
       1.50  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
1ADX804F 10/25/50  | 
       10/25/50   | 
       1.20  | 
       0.5±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
1ADX63805F 10/25/50  | 
       10/25/50   | 
       0.90  | 
       0.5±0.1  | 
       0.10  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.5%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
Ultra-high Precision Axis Probes

Ultra-high Precision Axis Probes
The length of probe could be customized; array probe is  optional  
     * We can add temperature sensor  in the probe
     * If test  frequency higher than 800Hz, suggest to choose non-metal packaging, inorder to  avoid affecting test accuracy  
     * Suitable  for DX-180, DX-210, DX-360
Model  | 
       L(cm)approx   | 
       D(mm) max  | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic    linearity (%rdg)  | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
1HADX800F 10/25/50  | 
       10/25/50   | 
       5.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC    | 
       ±0.03%/C°   | 
       Brass   | 
     
1HADX801F 10/25/50  | 
       10/25/50   | 
       3.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass   | 
     
1HADX802F 10/25/50  | 
       10/25/50   | 
       2.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
1HADX803F 10/25/50  | 
       10/25/50   | 
       1.50  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
1HADX804F 10/25/50  | 
       10/25/50   | 
       1.20  | 
       0.5±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.05%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.03%/C°   | 
        
          Brass    | 
     
1HADX805F 10/25/50  | 
       10/25/50   | 
       0.90  | 
       0.5±0.1  | 
       0.10  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.5%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.12 G/ºC   | 
       ±0.03%/C°   | 
       Brass   | 
     
Temperature Conpensation Type High Precision Axial Probes (installed temperature sensor)
Model  | 
       L(cm)approx   | 
       D(mm) max  | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic    linearity (%rdg)  | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
1ADX800FT 10/25/50  | 
       10/25/50   | 
       5.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
1ADX801FT 10/25/50  | 
       10/25/50   | 
       3.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass   | 
     
1ADX802FT 10/25/50  | 
       10/25/50   | 
       2.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass    | 
     
1ADX803FT 10/25/50  | 
       10/25/50   | 
       1.50  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
1ADX804FT 10/25/50  | 
       10/25/50   | 
       1.20  | 
       0.5±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+100°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass    | 
     
Temperature Conpensation Type High Temperature Resistance High Precision Axial Probes (installed temperature sensor)
Model  | 
       L(cm)approx   | 
       D(mm) max  | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic    linearity (%rdg)  | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
1ADX800FHT 10/25/50  | 
       10/25/50   | 
       5.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
1ADX801FHT 10/25/50  | 
       10/25/50   | 
       3.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass   | 
     
1ADX802FHT 10/25/50  | 
       10/25/50   | 
       2.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass    | 
     
1ADX803FHT 10/25/50  | 
       10/25/50   | 
       1.50  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
1AHD804FHT 10/25/50  | 
       10/25/50   | 
       1.20  | 
       0.5±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       30kG   | 
       ±0.2%to30kG   | 
       -10°Ct0+195°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass    | 
     
Temperature Conpensation Type Low Temperature Resistance High Precision Axial Probes (installed temperature sensor)
Model  | 
       L(cm)approx   | 
       D(mm) max  | 
       A(mm)   | 
       Active area (mm)   | 
       Frequency range   | 
       Full Scale (Standard)   | 
       magnetic    linearity (%rdg)  | 
       operating temp range   | 
       Temp coefficient (max) zero  | 
       Tempcoefficient (max)  | 
       stem material   | 
     
1ADX800FLT 10/25/50  | 
       10/25/50   | 
       5.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.2%to30kG   | 
       -269°Cto+75°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
1ADX801FLT 10/25/50  | 
       10/25/50   | 
       3.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.2%to30kG   | 
       -269°Cto+75°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass   | 
     
1ADX802FLT 10/25/50  | 
       10/25/50   | 
       2.00  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.2%to30kG   | 
       -269°Cto+75°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass    | 
     
1ADX803FLT 10/25/50  | 
       10/25/50   | 
       1.50  | 
       1±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.2%to30kG   | 
       -269°Cto+75°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
1ADX804FLT 10/25/50  | 
       10/25/50   | 
       1.20  | 
       0.5±0.1  | 
       0.15  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.2%to30kG   | 
       -269°Cto+75°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
        
          Brass    | 
     
1ADX805FL 10/25/50  | 
       10/25/50   | 
       0.90  | 
       0.5±0.1  | 
       0.10  | 
       DC-30KHZ   | 
       300kG   | 
       ±0.2%to30kG   | 
       -269°Cto+75°C   | 
       ±0.08 G/ºC   | 
       ±0.01%/C°   | 
       Brass   | 
     
High Frequency High Precision Axial Probes
Model  | 
        L(cm)approx   | 
        D(mm) max  | 
        A(mm)   | 
        Active area (mm)   | 
        Frequency range   | 
        Full Scale (Standard)   | 
        magnetic    linearity (%rdg)  | 
        operating temp range   | 
        Temp coefficient (max) zero  | 
        Tempcoefficient (max)  | 
        stem material   | 
      
1ADX800F-H 10/25/50  | 
        10/25/50   | 
        5.00  | 
        1±0.1  | 
        0.15  | 
        DC-50KHZ   | 
        30kG   | 
        ±0.2%to30kG   | 
        -10°Ct0+155°C   | 
        ±0.08 G/ºC    | 
        ±0.02%/C°   | 
        plastics  | 
      
1ADX801F-H 10/25/50  | 
        10/25/50   | 
        3.00  | 
        1±0.1  | 
        0.15  | 
        DC-50KHZ   | 
        30kG   | 
        ±0.2%to30kG   | 
        -10°Ct0+155°C   | 
        ±0.08 G/ºC   | 
        ±0.02%/C°   | 
        plastics  | 
      
1ADX802F-H 10/25/50  | 
        10/25/50   | 
        2.00  | 
        1±0.1  | 
        0.15  | 
        DC-50KHZ   | 
        30kG   | 
        ±0.2%to30kG   | 
        -10°Ct0+155°C   | 
        ±0.08 G/ºC   | 
        ±0.02%/C°   | 
        plastics  | 
      
1ADX803F-H 10/25/50  | 
        10/25/50   | 
        1.50  | 
        1±0.1  | 
        0.15  | 
        DC-50KHZ   | 
        30kG   | 
        ±0.2%to30kG   | 
        -10°Ct0+155°C   | 
        ±0.08 G/ºC   | 
        ±0.02%/C°   | 
        plastics  | 
      
1ADX804F-H 10/25/50  | 
        10/25/50   | 
        1.20  | 
        0.5±0.1  | 
        0.15  | 
        DC-30kHZ   | 
        30kG   | 
        ±0.2%to30kG   | 
        -10°Ct0+155°C   | 
        ±0.08 G/ºC   | 
        ±0.02%/C°   | 
        plastics  | 
      
   

 Hysteresis Graph Test System