Magnet Machine:3D measuring meter of the distribution of the magnetic fields,magnetic field meter logo
3D measuring meter of the distribution of the magnetic fields,magnetic field meter
Product Detail:

Lifting Electromagnets

Product Detail:

MW16 MW26 MW36 MW96 Series Lifting Electromagnet

Lifting ElectromagnetMW16, MW26, MW36, MW96 Series are electromagnets lifting steel strip with movable pole, suitable for lifting belt. There're three structures.

1. Vertical-lifting

MW26 and MW36 electromagnet adsorption end strip surface. When the strip end surface (Chart B surface) into convex and concave, Yamagata, the poor level of d "25mm, if vertical lifting. As telescopic pole can make free, and strip volumes will be good electromagnet face contact, lifting ability to play.

2. Level-rigger

MW16 series electromagnet adsorption strip the arc angle.

3. Universal

MW96 series of vertical lifting may also be lifting level.

Lifting Electromagnet

 

Main specification (duty cycle TD-50%) for MW26 series

Model
specifications
Normal temperature type
(100? below)
High temperature type
(650? below)
MW26-
185185L-H
MW26-
195195L-H
MW26-
225225L/H
MW26-
185185L/2-H
MW26-
195195L/2-H
Overall dimension A mm 1844 1950 1950 1844 1950
B 1353 1540 1630 1400 1600
C 250 250 250 250 250
D 170 180 180 170 180
E 70 90 90 70 90
F 100 60 60 100 60
Weight Kg 5400 5800 6300 5800 6300
Rated DC voltage V 220 220 220 220 220
Current
(cold)
A 54.5 65 74 49 58
Consumption
power(cold)
KW 11.8 14.3 16.28 16.28 12.76
Lifting Ability f2 1500 1630 1930 1500 1630
f1 700 700 700 700 700
weight 10 20 27 10 20

Main specification (duty cycle TD-50%) for MW36 series

Model
specifications
Normal temperature type
(100? below)
High temperature type
(650? below)
MW36-320L-H MW36-365L-H MW36-320L/2-H MW36-365L/2-H
Overall dimension  A mm 3200 3650 3200 3650
B 1650 1900 1750 2000
C 500 500 500 500
D 250 250 250 250
E 90 115 90 115
F 60 60 60 60
Weight Kg 9500 17600 11200 19500
Rated DC voltage V 220 220 220 220
Current
(cold-state)
A 145 188 125 165
Consumption
power(cold-state)
KW 31.9 41.36 27.5 36.3
Lifting Ability f2 Osteoporosis mm 3000 3400 3000 3400
Tight mm 1950 2100 1950 2100
f1 mm 700 700 700 700
Weight T 21 32 21 32

Note: to select other compatible equipments should be based on the rated voltage, power (current).