Product Catalog: |
Magnetic Field Coil
Product Detail: |
Helmholtz Coil
Helmholtz Coil, homogeneous area is big, and the use of the space is open, also easy to handle. It Can achieve that one-dimensional, two-dimensional and three-dimensional combination of magnetic field, provide ac and dc magnetic field, and electric current and magnetic field can have a good linear relationship. It apply to the institutes, institutions of higher learning and enterprises material or magnetic detection experiment, applied to materials, electronics, biological, medical, aerospace, chemical, applied physics and other subjects, Its main use: produce standard magnetic field; Offset and compensation of the earth's magnetic field, the magnetic environment simulation, judgment of magnetic shielding effect, electromagnetic interference simulation experiment, hall sensor and all kinds of magnetometer calibration, biological magnetic field research and the study of the magnetic properties of the material.
One-dimensiona coill:
The character of one-dimensional:Magnetic field is horizontal or vertical direction, space is open, can achieve relatively high magnetic field, and the highest magnetic field can reach 1000 gs. It apply to the standard field, hall sensor and all kinds of magnetometer calibration, biological magnetic field research and the study of the magnetic properties of the material.
Two-dimensional
The character of two-dimensional:The space of the magnetic field is open, the general direction is X axis and Z axis, and 2 d can reach 100 Gs at the same time. It apply to the standard field, hall sensor and all kinds of magnetometer calibration, biological magnetic field research and the study of the magnetic properties of the material.
The character of three-dimensional:Magnetic field, X, Y, Z axial magnetic field is implemented, general each axial magnetic field is low. Especially suitable for standard field, offset and compensation of the earth's magnetic field, the magnetic environment simulation, judgment of magnetic shielding effect, electromagnetic interference simulation experiment, hall sensor and all kinds of magnetometer calibration, biological magnetic field research and the study of the magnetic properties of the material.
Helmholtz Coil specification parameter
Coil type |
Radius (mm) |
Center magnetic field |
Uniformity |
Homogeneity sphere dameter(mm) |
Each dimension power range |
The One dimensional weight |
The three dimensional weight |
DXHC 30-50 |
300 |
50 |
5 |
200 |
420 |
55 |
|
1 |
150 |
||||||
DXHC 30-10 |
300 |
10 |
0.5 |
100 |
90-120 |
12 |
38 |
0.1 |
90 |
||||||
DXHC 30-2 |
300 |
2 |
0.05 |
60 |
18~32 |
3.5 |
11 |
0.01 |
40 |
||||||
DXHC 25-1000 |
250 |
1000 |
5 |
160 |
5000 |
500 |
|
1 |
125 |
||||||
DXHC 25-500 |
250 |
500 |
0.5 |
100 |
2500 |
250 |
|
0.1 |
75 |
||||||
DXHC 25-300 |
250 |
300 |
0.05 |
50 |
1600 |
150 |
|
0.01 |
33 |
||||||
DXHC 25-100 |
250 |
100 |
5 |
160 |
600 |
50 |
|
1 |
125 |
||||||
DXHC 25-50 |
250 |
50 |
0.5 |
100 |
300~620 |
30 |
138 |
0.1 |
75 |
||||||
DXHC 25-10 |
250 |
10 |
0.05 |
50 |
60~110 |
8 |
32 |
0.01 |
33 |
||||||
DXHC 25-2 |
250 |
2 |
5 |
160 |
12~18 |
4 |
14 |
1 |
125 |
||||||
DXHC 20-500 |
200 |
500 |
0.5 |
80 |
2000 |
160 |
|
0.1 |
60 |
||||||
DXHC 20-300 |
200 |
300 |
0.05 |
40 |
1000 |
96 |
|
0.01 |
26 |
||||||
DXHC 20-100 |
200 |
100 |
5 |
130 |
350 |
32 |
|
1 |
100 |
||||||
DXHC 20-50 |
200 |
50 |
0.5 |
80 |
200~520 |
16 |
54 |
0.1 |
60 |
||||||
DXHC 20-10 |
200 |
10 |
0.05 |
40 |
40~65 |
8 |
28 |
0.01 |
26 |
||||||
DXHC 20-5 |
200 |
5 |
1 |
100 |
20~32 |
6 |
22 |
0.1 |
60 |
||||||
DXHC 20-2 |
200 |
2 |
1 |
100 |
8~10 |
4 |
15 |
0.1 |
60 |
||||||
DXHC 15-300 |
150 |
300 |
5 |
100 |
660 |
54 |
|
1 |
75 |
||||||
DXHC 15-100 |
150 |
100 |
0.5 |
60 |
220 |
18 |
|
0.1 |
45 |
||||||
DXHC 15-50 |
150 |
50 |
0.05 |
30 |
110~330 |
12 |
38 |
0.01 |
20 |
||||||
DXHC 15-10 |
150 |
10 |
1 |
75 |
21~42 |
6 |
24 |
0.1 |
45 |
||||||
DXHC 10-200 |
100 |
200 |
5 |
66 |
200 |
19 |
|
1 |
50 |
||||||
DXHC 10-100 |
100 |
100 |
0.5 |
40 |
100 |
15 |
|
0.1 |
30 |
||||||
DXHC 10-50 |
100 |
50 |
0.05 |
20 |
50~180 |
9 |
20 |
0.01 |
10 |
||||||
DXHC 10-10 |
100 |
10 |
1 |
50 |
10~24 |
3.5 |
13 |
0.1 |
30 |
||||||
DXHC 7-100 |
70 |
100 |
5 |
45 |
50 |
7 |
|
1 |
35 |
||||||
DXHC 7-50 |
70 |
50 |
0.5 |
28 |
24~120 |
5 |
17 |
0.1 |
21 |
||||||
DXHC 7-10 |
70 |
10 |
0.05 |
14 |
5~24 |
2 |
8 |
0.01 |
9.3 |
Examples
NO |
Name |
Model |
Main technial parameters |
Product picture |
1 |
One-dimensional |
DXHC10-100 |
Magnetic field direction is level, the highest field strength is 200 gs, the average diameter is 200 mm, homogeneity Φ 30 * 30 mm, evenness 0.1% power is 200 w |
|
2 |
One-dimensional |
DXHC10-10 |
Magnetic field direction is level, the highest field strength is 10 gs, the average diameter is 200 mm, homogeneity Φ 30 * 30 mm, evenness 0.1% power is 10 w |
|
3 |
One-dimensional |
DXHC10-200 |
Magnetic field direction is level, the highest field strength is 200 gs, the average diameter is 200 mm, homogeneity Φ 30 * 30 mm, evenness 0.1% power is 200 w |
|
4 |
One-dimensional |
DXHC20-10 |
Magnetic field direction is level, the highest field strength is 10 gs, the average diameter is 400 mm, homogeneity Φ 100 * 100mm, evenness 1% power is 40 w |
|
5 |
One-dimensional |
DXHC20-200 |
Magnetic field direction is level, the center field strength is 200 Gs, Magnetic field uniformity is 1*10-3 ,the average diameter is 400 mm, homogeneity Φ 60 * 60 mm,power is 700 w(10A70V) |
|
6 |
Two-dimensional |
2DXHC20-100 |
Magnetic field direction of X axis and Z axis orthogonal to each other, the X axis highest magnetic field intensity is 100 gs, Z axis is 1 gs. Minimum average diameter is 400 mm, homogeneity sphere Φ is 55 mm, evenness0.1%, the X axis power is 350 w. |
|
7 |
Two-dimensional |
2DXHC11-240 |
Magnetic field direction of X axis and Z axis orthogonal to each other, the X axis horizontal rotating magnetic field, the X axis highest magnetic field intensity is 240 gs, and Z axis also is 240 gs. Minimum average diameter is 220 mm, homogeneity sphere Φ 30 mm, evenness0.1%, the X axis power is 800 w / 2800 w. |
|
8 |
Three-dimensional |
3DXHC20-1 |
3 d coil, magnetic field direction X, Y, Z axis orthogonal to each other, each axial magnetic field strength highest 1.0 Gs, minimum average diameter is 400 mm, homogeneity sphere Φ is 55 mm, evenness 0.1%, each power is 10 w. |
|
9 |
Three-dimensional |
3DXHC15-30 |
3 d coil, magnetic field direction X, Y, Z axis orthogonal to each other, the highest magnetic field instensity is 30 Gs minimum average diameter is 300 mm, homogeneity sphere Φ is 40 mm, 0.1% uniformity, each shaft power is 120 w. |
|
10 |
Three-dimensional |
3DXHC20-10 |
3 d coil, magnetic field direction X, Y, Z axis orthogonal to each other, the highest magnetic field instensity is 10 Gs minimum average diameter is 400 mm, homogeneity sphere Φ is 100 mm, 1% uniformity, each shaft power is 64 w. |
|
11 |
Three-dimensional |
3DXHC21-25 |
Each dimensional center field strength is 25 gs; Magnetic field uniformity is 1 * 10-3; Homogeneous area is Φ 60 * 60 mm; The minimum diameter is 420 mm, maximum diameter is 650 mm; |
|
12 |
One-dimensional |
DXHC50-1 |