DX-360 Intelligent Digital Three Dimensional Gauss / Tesla Meter

DX-360 Gauss / Tesla Meter Detail:

DC Measurement(DC):

DC display resolution 5 ¾ (6 digital filter display)  

DX-1800 *0-3mT 0-30mT 0-300mT 0-3T *0-10T
Resolution 0.00001mT 0.0001mT 0.001mT 0.01mT 0.1mT

Marked * are the Automatic identification rangs of low magnetic field probe and ultra-high magnetic field probe
DC Accuracy: ±0.15% of reading ±0.005% of range
DC Temperature Coefficient:±(0.015% ±1 count)/ ºC
Acquisition Speed: 10/s

AC Effective Values(AC) and Frequency Measurement
AC Display Resolution: 0.001mT
AC RMS Frequency Range: 20Hz-30kHz
AC RMS Accuracy: ±1% of reading ±0.3% of range
AC RMS Frequency Response: 20Hz-2000Hz
Acquisition Speed: 10/s

Front Panel

Display: value of X,Y,Z axis, pitch angle value, clip angle value,date,time,temperature
Display Type: 800 x 480 Pixel,7 inch full view color screen
Display Resolution: 5 ¾ (6 digital filter display)
Display Update Rate:3rdg /s
Display Units: Gauss(G), Tesla(T), Amps/m(A/m), Oster(Oe)
Unit Multiplier: m,k,M
Definitions of control keys: AC/DC Switch, Measurement Units, Range Switch, Data Storage, Up/Down/Left/Right Direction, Menu, Max/Min/Interface Lock, Zero Mode, Confirmation Button, Relative Mode, Reset Mode
Keyboard: 14 membrane keys
Front Panel Features: Good Communication Ability, Intuitive Operation, Display Hints, Brightness Control, Panel Lock, Graphic Display

Probe Specifications

Input Type: Three dimensional Hall Effect Sensor
Probe Features: Linearity Compensation, Temperature Compensation, Auto Probe ZeroProbe
Compatibility: Standard probe or special probe  
Connector: 15 pin D-type

Interface Features

RS - 232C interface function  
Baudrate: 19600, 57600, 115200
Connector: 9 pin D-type, Terminal Configuration    
Software Suppot: Standard interface definition
Analog output monitoring
Configuration: Real-time analog voltage output
Rang: ± 3 V
Frequency Response: 20Hz to 3000Hz
Accuracy: depending on probes
Minimum load resistance: 1 k (Short-Circuit Protection)
Connector: BNC

General Parameters

Chassis: Metal shielded
Environment Temperature: 15℃to 35℃rated accuracy; 5℃to 40℃accuracy reducing                                                                                                      
Power Requirements: 220-240(+5 %, -10 %), 50 or 60Hz
Size: 460 mmWidth× 160mmheight× 465mm
Weight:8kg