Product Detail: |
Bipolar Program-controlled Power Supply
Model: DXKDP series
Bipolar Program-controlled Power Supply
DXKDP series bipolar programmable DC power supplies are high performance DC power supplies, specially researched and developed for scientific research and industrial departments’ power supply automation control application. These products have features of high accuracy, high stability, perfect over-voltage protection, over temperature protection and high reliability. The voltage, current and time can be set by panel keyboard or PC, to realize programmable automatic control.
Product features:
- Small size, light weight, suitable for work surface using and rack mounting;
- Small size, light weight, standard 19-inch mounting dimension, suitable for work surface using and rack mounting;
- With OLED display, more striking and clearer;
- With the keyboard buttons and knobs to control, easy to use;
- English and Chinese menu operation can be chosen, can set password protection;
- Built-in 10 groups of programmable control, each group with 99 steps to control the output of voltage, current and time;
- Standard analog signal output and RS-232 (RS-485) control interface;
- With over voltage protection and over current protection and over temperature protection, comprehensive and reliable protection;
- This product has voltage detection terminal of load terminal, with function of accurately reading and controlling the load terminal voltage.
Note: installation accessories for 12KW and 15KW 19 inch rack-mounted power supplies will be provided freely if need.
Note: this accessory will be use if user uses RS-485
Program control function:
Specifications:
Model |
Power |
Current |
Voltage |
Model of applied electromagnet |
DXKDP-300 |
0.3KW |
0.01A~10A |
0.01V~30V |
50 |
DXKDP-600 |
0.6KW |
0.01A~10A |
0.01V~60V |
60, 80 |
DXKDP-1300 |
1.3KW |
0.01A~10A |
0.1V~130V |
100 |
DXKDP-2000 |
2.0KW |
0.01A~16A |
0.1V~125V |
100 |
DXKDP-3750 |
3.8KW |
0.01A~25A |
0.1V~150V |
130 |
DXKDP-6000 |
6.0KW |
0.01A~40A |
0.1V~150V |
175 |
DXKDP-8000 |
8.0KW |
0.01A~50A |
0.1V~160V |
178, 200 |
DXKDP-10K |
10.0KW |
0.01A~50A |
0.1V~200V |
200, 220 |
DXKDP-12K |
12.0KW |
0.01A~60A |
0.1V~200V |
250, 280 |
DXKDP-15K |
15.0KW |
0.01A~75A |
0.1V~200V |
300 |
DXKDP-20K |
20.0KW |
0.01A~80A |
0.1V~250V |
380 |
DXKDP-30K |
30.0KW |
0.1A~120A |
0.1V~250V |
400 |
Special specifications can be customized according to user’s requirements
Technical parameters:
Item |
Parameters |
AC Input |
Single phase AC220V±10% (6KW and below) |
Three phase AC380V±10% (above 6KW) | |
50Hz/60Hz | |
Output Voltage |
0-rated voltage |
Output Current |
0-rated current |
Output Power |
Rated power |
Output-voltage Stability |
≦0.3%+10mV |
Load Stability |
≦0.5%+30mV |
Voltage Ripple |
≤0.5%+10mV (rms) |
Voltage Value Display |
4 digital bits Accuracy: ±1% +1 bit (10%-100%rated value) |
Display Format 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V | |
Current Value Display |
4 digital bits Accuracy: ±1% +1 bit (10%-100%rated value) |
Display Format 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A | |
Menu Display |
64*128 dot matrix OLED display |
Over Voltage Protection |
OVP can be set through menu, the protective value can be set freely; the output will be turned off after protection. |
Over Current Protection |
OCP can be set through menu, the protective value can be set freely; the output will be turned off after protection. |
Over Temperature Protection |
With OTP inside, the protective value is 85℃±5% (heat sink temperature); the output will be turned off after protection. |
Voltage Setting |
Menu settings, input with keyboard or encoder knob |
Current Setting |
Menu settings, input with keyboard or encoder knob |
State storage capacity |
10 groups of programmable control, each group with 99 steps to control the output of voltage, current and time |
Control Connection |
Standard analog signal output RS - 232 (RS-485) control interface |
Output Polarity |
Output positive (+) and negative (-) can be arbitrary grounding, Bipolar contactless commutation |
Heat-dissipating method |
Forced air cooling |
Operational Environment |
Temperature: 0℃~40℃; Humidity: 10%~85%RH |
Storage Environment |
Temperature: -20℃~70℃; Humidity: 10%~90%RH |
Note: all values are the typical values, so under the condition of different load or other conditions it will bigger than this value. The accuracy is measured in the state of voltage detection of load terminal, the possible deviation between actual value and the rating under the condition of temperature error and element aging. |