logo
Bipolar Program-controlled Power Supply
Product Detail:

Bipolar Program-controlled Power Supply

Model: DXKDP series

Bipolar Program-controlled Power Supply    DXKDP series bipolar programmable DC power supplies

Bipolar Program-controlled Power Supply

DXKDP series bipolar programmable DC power supplies are high performance DC power supplies, specially researched and developed for scientific research and industrial departments’ power supply automation control application. These products have features of high accuracy, high stability, perfect over-voltage protection, over temperature protection and high reliability. The voltage, current and time can be set by panel keyboard or PC, to realize programmable automatic control.

Product features:

  1. Small size, light weight, suitable for work surface using and rack mounting; Unipolar DC Power Supply
  2. Small size, light weight, standard 19-inch mounting dimension, suitable for work surface using and rack mounting;
  3. With OLED display, more striking and clearer;
  4. With the keyboard buttons and knobs to control, easy to use;
  5. English and Chinese menu operation can be chosen, can set password protection;
  6. Built-in 10 groups of programmable control, each group with 99 steps to control the output of voltage, current and time;
  7. Standard analog signal output and RS-232 (RS-485) control interface;
  8. With over voltage protection and over current protection and over temperature protection, comprehensive and reliable protection;
  9. This product has voltage detection terminal of load terminal, with function of accurately reading and controlling the load terminal voltage.

Note: installation accessories for 12KW and 15KW 19 inch rack-mounted power supplies will be provided freely if need.

Bipolar Program-controlled Power SupplyNote: this accessory will be use if user uses RS-485

 

Program control function:

Unipolar DC Power Supply

 

Specifications:

Model
Power
Current
Voltage
Model of applied electromagnet
DXKDP-300
0.3KW
0.01A~10A
0.01V~30V
50
DXKDP-600
0.6KW
0.01A~10A
0.01V~60V
60, 80
DXKDP-1300
1.3KW
0.01A~10A
0.1V~130V
100
DXKDP-2000
2.0KW
0.01A~16A
0.1V~125V
100
DXKDP-3750
3.8KW
0.01A~25A
0.1V~150V
130
DXKDP-6000
6.0KW
0.01A~40A
0.1V~150V
175
DXKDP-8000
8.0KW
0.01A~50A
0.1V~160V
178, 200
DXKDP-10K
10.0KW
0.01A~50A
0.1V~200V
200, 220
DXKDP-12K
12.0KW
0.01A~60A
0.1V~200V
250, 280
DXKDP-15K
15.0KW
0.01A~75A
0.1V~200V
300
DXKDP-20K
20.0KW
0.01A~80A
0.1V~250V
380
DXKDP-30K
30.0KW
0.1A~120A
0.1V~250V
400

Special specifications can be customized according to user’s requirements

Technical parameters:

Item
Parameters
AC Input
Single phase AC220V±10% (6KW and below)
Three phase AC380V±10% (above 6KW)
50Hz/60Hz
Output Voltage
0-rated voltage
Output Current
0-rated current
Output Power
Rated power
Output-voltage Stability
≦0.3%+10mV
Load Stability
≦0.5%+30mV
Voltage Ripple
≤0.5%+10mV (rms)
Voltage Value Display
4 digital bits   Accuracy: ±1% +1 bit (10%-100%rated value)
Display Format  0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V
Current Value Display
4 digital bits    Accuracy: ±1% +1 bit (10%-100%rated value)
Display Format  0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A
Menu Display
64*128 dot matrix OLED display
Over Voltage Protection
OVP can be set through menu, the protective value can be set freely; the output will be turned off after protection.
Over Current Protection
OCP can be set through menu, the protective value can be set freely; the output will be turned off after protection.
Over Temperature Protection
With OTP inside, the protective value is 85℃±5% (heat sink temperature); the output will be turned off after protection.
Voltage Setting
Menu settings, input with keyboard or encoder knob
Current Setting
Menu settings, input with keyboard or encoder knob
State storage capacity
10 groups of programmable control, each group with 99 steps to control the output of voltage, current and time
Control Connection
Standard analog signal output RS - 232 (RS-485) control interface
Output Polarity
Output positive (+) and negative (-) can be arbitrary grounding, Bipolar contactless commutation
Heat-dissipating method
Forced air cooling
Operational Environment
Temperature: 0℃~40℃; Humidity: 10%~85%RH
Storage Environment
Temperature: -20℃~70℃; Humidity: 10%~90%RH
Note: all values are the typical values, so under the condition of different load or other conditions it will bigger than this value. The accuracy is measured in the state of voltage detection of load terminal, the possible deviation between actual value and the rating under the condition of temperature error and element aging.